Button Control¶
A USB button pad plugged into the robot host lets an operator start, stop, and discard demonstrations without touching a keyboard or the terminal. This matters when the operator has both hands on the leader arms.
How it works¶
The pad is read through the Linux input layer (/dev/input/event*) by the
EvdevKeyboard node, which runs on the machine the pad is plugged into. Because it
reads the kernel device directly, it needs no graphical session, no controlling
terminal, and no window focus. A script launched over SSH still sees presses on a pad
attached to the robot host.
Presses become Command values, which the control loop consumes. The command is
independent of which device raised it, so the same workflow can later be driven from a
different input source without changing the loop.
| Command | Meaning |
|---|---|
TOGGLE_EPISODE |
Start recording a demonstration, or stop and save the one in progress |
DISCARD_LAST |
Delete the most recently saved demonstration |
TOGGLE_INFERENCE |
Start or stop the policy inference loop |
GO_HOME |
Return the robot to its home pose, ready for another trial |
One button covers both halves of TOGGLE_EPISODE: pressing it while idle starts an
episode, pressing it again stops and saves. This is what lets a small pad run a full
collection session.
One-time host setup¶
/dev/input/event* is owned by root:input with mode 0660. A local desktop session
is granted access automatically, but an SSH session is not, so without this step the
device is invisible to a script started over SSH — and evdev reports no devices
rather than a permission error.
Install the udev rule from the hardware repository:
sudo cp rio-hw/scripts/setup/buttons/99-rio-buttons.rules /etc/udev/rules.d/
sudo udevadm control --reload-rules && sudo udevadm trigger
Then unplug and replug the pad. To grant an existing user access without a rule change,
add them to the input group instead — note the session must be fully reconnected
afterwards, since group membership is fixed at login:
Verify the pad is visible:
Station configuration¶
Declare the pad as a node in the station config. Matching by USB id means the device node number does not matter, so nothing breaks when devices re-enumerate after a reboot:
buttons: str | None = "EvdevKeyboard"
buttons_module: str = "interfaces"
buttons_cfg: NodeCfg | None = field(
default_factory=lambda: NodeCfg(
vendor_id=0x3553, # find with `lsusb`
product_id=0xC011,
grab=True, # keep presses out of the operator's shell
freq=100,
)
)
button_bindings: dict[str, str] = field(
default_factory=lambda: {
"a": "TOGGLE_EPISODE",
"c": "DISCARD_LAST",
}
)
Bind by character ("a") or by raw Linux input-event code (30) when a button sends
something without a character. grab=True takes exclusive access, so presses do not also
land in whatever shell has the terminal; leave it off for a keyboard the operator also
types on.
The buttons drive the recorder, so it must be enabled — several station configs ship
with recorder = None for testing, and with it unset a press is logged and ignored:
Set start_recording=False so the first episode begins on a button press rather than at
startup:
recorder_cfg: RecorderCfg = field(
default_factory=lambda: RecorderCfg(path=f"data/{TASK}/", start_recording=False)
)
Any pad works — the node is not specific to one model. Find a new pad's USB ids with
lsusb, and its keycodes with the device listing script above.
Collecting data¶
Teleoperation goes live immediately. The terminal prints a colour-coded banner on every state change, so the current state is readable across the room:
| Banner | Meaning |
|---|---|
IDLE (white) |
Ready. Press the start button to begin an episode |
RECORDING (red) |
Recording. Press again to stop and save |
SAVING (yellow) |
Writing to disk. Buttons are ignored until it finishes |
DISCARD_LAST only applies between episodes; pressing it mid-episode is refused and
logged, so a mispress cannot destroy a demonstration being recorded. The discarded
trajectory's index is reused by the next episode, so numbering has no gaps.
Policy inference¶
STATION=BimanualYamStation POLICY=MolmoAct2BimanualYamCfg uv run python -m examples.policy_inference
Inference starts stopped when buttons are configured, so the robot does not move until someone presses start. The bound buttons then toggle inference and return the robot home between trials.
Stopping and restarting inference re-reads the robot's actual pose and discards any pending action chunk, so a chunk computed before the pause is never replayed against a robot that has since moved.
Going home¶
GO_HOME stops inference first, then drives the robot to home_pose along a cosine
ease-in-out ramp over home_duration seconds — accelerating from rest and arriving at
rest. It never commands the home pose directly: that would ask the arm to cross the whole
distance in a single control cycle.
# Action layout: six joints then gripper, per arm. Zero joints, both grippers open.
home_pose: list[float] | None = field(
default_factory=lambda: [0.0] * 6 + [1.0] + [0.0] * 6 + [1.0]
)
home_duration: float = 5.0 # raise for a gentler return
Leave home_pose unset and it defaults to every joint at zero with the grippers open,
with the gripper positions discovered from the embodiment rather than hard-coded.
Inference stays stopped after homing; press the start button again for the next trial.
Homing is not available during leader-follower teleoperation. The leader arms run in zero-gravity mode and ignore position commands, so homing the followers while the leaders stayed put would snap the followers back to the leader pose on the next cycle.
Running without buttons¶
Buttons are optional in both scripts. If the station declares none, or declares a pad that is not currently plugged in, the script warns once and runs without it:
- Data collection prompts for Enter, then records the whole session as a single trajectory and saves it on Ctrl-C — the behaviour from before buttons existed.
- Policy inference prompts for Enter and then runs continuously, with no homing available.
A declared-but-absent pad costs a short startup delay while the node waits to become
ready; timeout in buttons_cfg bounds it. The node prints its own traceback in that
case, which is informational — the warning that follows says the script is continuing.
Notes¶